-40%

BERNZOMATIC 14.1oz. MAP-Pro Disposable RTU High Heat Brazing Torch Fuel Cylinder

$ 11.16

Availability: 26 in stock
  • Condition: New
  • Custom Bundle: No
  • Country/Region of Manufacture: United States
  • Modified Item: No
  • Brand: Bernzomatic
  • All returns accepted: ReturnsNotAccepted
  • Gas Type: Map-Pro
  • MPN: 332477
  • Item Type: Fuel Cylinder

    Description

    It is buyers responsibility to read full description and included safety information before purchasing. Seller is not responsible for any incidents involving this item. Improper use can result in injury or death.
    Product
    must be used in a well ventilated area due to the accumulation of carbon monoxide, this unseen and odorless gas is deadly
    in
    small
    amounts
    .
    *Product labeling may have slight variations from listing images. Guaranteed to be authentic Bernzomatic MAP-PRO FUEL
    Great for Brazing Steel, Removing rusted Bolts and Soldering large diameter copper pipes and many other applications
    .
    Product Overview
    Flame temperature in air of 3,730° F/2054.4° C
    Faster heat transfer than propane fuel
    Durable steel construction
    Model#: 332477
    Sku#: 602226
    Internet#: 203226566
    Work faster and more efficiently with a higher burn temperature than standard propane. The Bernzomatic MAP-Pro Hand Torch Cylinder contains premium fuel suited for a variety of job site projects including soldering large copper pipes, brazing and heat treating. Constructed of durable steel, the slim, lightweight cylinder is easy to grip and maneuver. Flame temperature in air is 3,730 degrees Fahrenheit.
    Flame temperature in air of 3,730° F / 2054.4° C, ideal for medium to heavy soldering and brazing
    Faster heat transfer than propane fuel
    Slim, lightweight cylinder is easy to grip and maneuver
    Durable steel construction
    Technical Specifications
    Product Identifier: Max Power Propylene (Odorized)
    Synonyms: Methyl ethylene, Propane
    Chemical Family: Olefins
    Chemical Formula: C3H6
    Application and Use: Multi-purpose fuel or chemical feedstock
    Product Description: Colorless, Hydrocarbon odor composed, stored and handled as liquids under pressure DOT Hazard Class: Flammable Gas
    C.A.S. Number: 115-07-1
    UN 1077
    -HEALTH HAZARD INFORMATION NATURE OF HAZARD
    INHALATION:
    May cause central nervous system disorder (e.g. loss of coordination, weakness, fatigue, mental confusion and blurred vision) and/or damage.
    Breathing high vapor concentrations (saturated vapors) for a few minutes may be fatal. Saturated vapors can be encountered in confined spaces and/or under conditions of poor ventilation.
    May cause irritation, breathing failure, coma and death without any warning odor being sensed.
    Inhalation exposure to this product at extremely high concentrations, as in accidental releases in which concentrations reach or exceed the flammable range, may result in cardiac arrhythmias.
    EYE CONTACT:
    Vapors may cause a slight irritation and liquid contact with the eye may cause blindness.
    SKIN CONTACT:
    Exposure to rapidly expanding gas or vaporizing liquid may cause frostbite (cold burns)
    INGESTION:
    Not considered to be a hazard
    INHALATION:
    Exposure to low concentrations may result in a mild anesthetic action. Only exposures to extremely high concentrations will result in physiological effects.
    SYSTEMIC AND OTHER EFFECTS:
    In human studies, propylene at very high concentrations has caused tearing, coughing, and vomiting.
    CARCINOGENICITY:
    No evidence has been listed by the NTP and is listed by the IARC as “not classifiable as to its’ carcinogenicity to humans”.
    TERATOLOGY:
    No evidence.
    REPRODUCTIVE EFFECTS:
    No evidence has been listed.
    -FIRST AID MEASURES
    INHALATION:
    In emergency situations use proper respiratory protection to immediately remove the affected victim from exposure. Administer artificial respiration if breathing has stopped. Keep at rest. Call for prompt medical attention.
    EYE CONTACT:
    In case of cold burns caused by rapidly expanding gas or vaporizing liquid, get prompt medical attention.
    SKIN CONTACT:
    In case of cold burns caused by rapidly expanding gas or vaporizing liquid, get prompt medical attention.
    INGESTION:
    Do NOT induce vomiting if liquid propylene has been swallowed. Seek immediate medical attention.
    -PREVENTITIVE AND CORRECTIVE MEASURES
    PERSONAL PROTECTION:
    The selection of personal protective equipment varies, depending upon conditions of use. In open systems where contact is likely, wear gas-proof goggles, face shield, chemical resistant overalls, and appropriate thermal/chemical gloves. Where skin and eye contact is unlikely, but may occur as a result of short and/or periodic exposures, wear long sleeves, chemical resistant gloves, gas-proof goggles, and a face shield.
    Where concentrations in air may exceed the occupational exposure limits given in Section 4 and where engineering, work practices or other means of exposure reduction are not adequate, approved respirators may be necessary to prevent overexposure by inhalation.
    ENGINEERING CONTROLS:
    The use of local exhaust ventilation is recommended to control emissions near the source. Laboratory samples should be handled in a fume hood. Provide mechanical ventilation of confined spaces. Use explosion-proof ventilation equipment.
    HANDLING, STORAGE AND SHIPPING:
    Keep containers closed. Handle and open containers with care.
    Store in a cool, well-ventilated place away from incompatible materials. Store as pressurized liquid in a pressure vessel. Store and load the container at normal (up to 38 deg C) temperature and at atmospheric pressure.
    Material will accumulate static charges which may cause a spark. Static charge build-up could become an ignition source, Use proper relaxation and grounding procedures.
    Empty containers may contain product residue. Do not pressurize, cut, heat or weld empty container. Do not reuse empty containers without commercial cleaning or reconditioning.
    LAND SPILL:
    Eliminate source of ignition. Keep away, Prevent additional discharge of material, if possible to do so without hazard. Vapors or dust may be harmful or fatal. Warn occupants of downwind areas.
    Allow to evaporate.
    Consult an expert on disposal of recovered material. Ensure disposal in compliance with government requirements and ensure conformity to local disposal regulations. Notify the appropriate authorities immediately.
    Take all additional action necessary to prevent and remedy the adverse effects of the spill.
    WATER FILL:
    Eliminate source of ignition. Vapors or dust may be harmful or fatal. Warn occupants and shipping in downwind area. Allow to evaporate from surface.
    Consult an expert on disposal of recovered material. Ensure disposal in compliance with government requirements and ensure conformity to local disposal regulations. Notify the appropriate authorities immediately.
    Take all additional action necessary to prevent and remedy the adverse effects of the spill.
    -FIRE AND EXPLOSION HAZARD
    Flashpoint: -162 deg F
    Auto ignition: 860 deg F (460 deg C) Flammable Limits: LEL 2.0% UEL 11.1%
    GENERAL HAZARDS:
    Extremely flammable: material will readily ignite at normal temperatures.
    Flammable Gas: may readily form flammable mixtures at or above the flash point.
    Toxic gases will form upon combustions.
    Static Discharge: material may accumulate static charges which may cause a fire.
    Auto-refrigeration: drains may become plugged and valves may become inoperable because of the formation of ice due to expanding vapors or vaporizing liquids.
    FIRE FIGHTING:
    Use water spray to cool fire exposed surfaces and to protect personnel.
    Shut off fuel to fire if possible to do so without hazard. If a leak or spill has not ignited use water spray to disperse the vapors. Do not extinguish flames at leak because possibility of uncontrolled explosive re-ignition exists. Cut off fuel and/or allow fire to burn out.
    Extinguish small residual fires with dry chemical powder or water spray.
    Try to cover liquid spills with foam.
    Respiratory and eye protection required for fire fighting personnel.
    A self-contained breathing apparatus (SCBA) should be used for all indoor fires and any significant outdoor fires. For small outdoor fires, which may easily be extinguished with a portable fire extinguisher, use of a SCBA may not be required.
    HAZARDOUS COMBUSTION PRODUCTS:
    Smoke, carbon monoxide, carbon dioxide under thermal decomposition.